1, the motor reversal or transfer belt loose, broken. Should adjust power phase sequence, adjust or replace the belt tensioner;
2, oil separator fault; ① tanker filters (including conical strainer) congested. Filters should be cleaned to remove debris; ② oil separator valve stuck untapped oil tanker caused no oil. Maintenance should remove the oil valve, re-installed after clearing the debris, so that it can move up and down freely; ③ small oil separator float into the oil or fall off, resulting in a high-pressure hyperbaric chamber can also cause cng fuel dispenser ④ oil separator pressure pad superstructure damage caused by high-pressure chamber communicating with the pressure chamber, resulting in high-pressure hyperbaric chamber not form leaving no oil tanker; no oil. ⑤ hydrocarbon human separator filter pads or spring seat damage. Replace damaged gaskets; ⑥ oil separator cone valve is not shutting.
3, vane pump failure; ① vane pump relief valve is not closed. Due to a foreign body (broken shrapnel, etc.) between the relief valve stuck in the valve and valve seat, causing the fluid inside the loop always do and can not flow in the pump, repairs should remove the spool, remove foreign bodies seat; ② Because the pump with the rotor blades and the shrapnel long do high-speed operation, due to fatigue and wear, fracture, resulting in vane pump discharge increases, even when serious loss of pumping action, the pump should be cleared of debris and repair damaged leaves, shrapnel, re-installed after replacing new; ③ vane pump and gas separator combined with the surface of the pump pad breakdown or anti-loaded, can also cause vane pump high-pressure chamber communicates with the low pressure chamber, resulting in the loss of the oil discharge vane pump function; ④ vane pump loose rotor and the rotor shaft, causing the shaft idle, then repair or replace the rotor blades need to diesel hand pump
The temperature probe is generally a thermocouple or RTD, thermocouple temperature voltage changes, the thermal resistance temperature resistance change, that is good.
2015年2月24日星期二
2014年12月31日星期三
measurement of the temperature
Standards of measurement of the temperature and the temperature of the test work, usually by being seized on a standard thermometer and method comparison standard thermometer, done that comparison. Due to the large range of gas dispensersscale temperature range specified interpolation different temperature zones of different instruments, but the actual temperature measuring instruments for the applicable temperature range is different, so the different temperature zones and types of measuring instruments which measurement methods are different. Various industries and regions thermometer traceable to standard equipment in all sectors and regions, thermometer calibration used in the construction industry can be traced back to the local metering station and then traced to China, China Institute of Metrology fuel dispensing hose reference, can be traced to China Building Science School building Energy and environmental Monitoring Center, and then finally traced to a Chinese benchmark China Institute of temperature measurement.
订阅:
评论 (Atom)